Define your requirements
15717 Technical documents
-
W-J-3167
(Approval document / Penetration)
Blank or cables through CP 653 Speed Sleeve
English
Related products: CP 606 Firestop acrylic sealant
-
W-J-5134
(Firestop System Details / UL Detail Drawing)
Max. 4" steel, cast iron, or copper with 1-1/2"glass fiber insulation
English
Related products: CP 606 Firestop acrylic sealant
-
F-E-1018
(Approval document / Penetration)
Max. 1" flexible steel conduit or gas piping (max qty = 3) (AS=0" to 1-1/4")
English
Related products: CP 606 Firestop acrylic sealant
-
W-J-1193
(Approval document / Penetration)
Max. 12" steel, cast iron, max. 6" copper or steel conduit (sleeved)
English
-
W-J-5041
(CAD/BIM Typicals / Auto CAD drawing file)
Max. 4" steel or max. 2" Copper with 3/4" AB/PVC insulation (AS=0" to 1-1/2")
English
-
F-C-5066
(Approval document / Penetration)
Max. 4" copper, cast iron or steel pipe with 1-1/2" glass fiber
English
Related products: CP 606 Firestop acrylic sealant
-
W-J-1193
(Firestop System Details / UL Detail Drawing)
Max. 12" steel, cast iron, max. 6" copper or steel conduit (sleeved)
English
-
W-J-3168
(Firestop System Details / UL Detail Drawing)
Blank or cables through CP 653 Speed Sleeve
English
-
W-J-4029
(CAD/BIM Typicals / Auto CAD drawing file)
Cable Tray
English
Related products: CFS-BL Firestop Block
-
F-C-8026
(CAD/BIM Typicals / Auto CAD drawing file)
Double HVAC Line Set (pvc drain)
English
-
W-J-3110
(Approval document / Penetration)
Cable bundle (various cables) through Unique Split Sleeve
English
Related products: CP 618 Firestop putty stick
-
F-A-6002
(Firestop System Details / UL Detail Drawing)
Electrical busway (23" x 4-1/2") (AS=1/2" to 6-1/2")
English
-
F-C-7025
(Firestop System Details / UL Detail Drawing)
Max. 10" diameter (min. 28 Ga) or 4" diameter (min. 30 Ga) sheet metal duct w/o damper
English
Related products: CP 606 Firestop acrylic sealant
-
F-C-8032
(Firestop System Details / UL Detail Drawing)
Double HVAC Line Set (no pvc drain)
English
Related products: CP 606 Firestop acrylic sealant
-
F-E-8008
(Approval document / Penetration)
HVAC Line Set
English
-
W-J-5028
(Approval document / Penetration)
Max. 12" steel or max 6" copper with 1-1/2" glass fiber insulation (sleeved)
English
-
F-C-8044
(Approval document / Penetration)
Multiple penetrating items (metal, insulated, PEX, cables) through 14" x 5-1/2" block out (AS=0" to 1-1/2")
English
-
F-C-5037
(Approval document / Penetration)
Max. 2" copper, or steel pipe with max. 3/4" AB/PVC insulation
English
-
W-J-3196
(CAD/BIM Typicals / Auto CAD drawing file)
Blank or Cables (various) through Firestop Cable Transit
English
Related products: CFS-T cable transit wedge puller, CFS-T cable module
-
F-A-5015
(Approval document / Penetration)
Max. 4" steel or copper pipe with nominal 3/4" AB/PVC insulation (2-1/2" concrete)
English
Related products: CP 680-M Cast-in firestop sleeve, CP 680-P Cast-in firestop sleeve